- Single room: about 2.5 kW for a bedroom up to 20 square metres, 5 kW for a 30 to 40 square metre living room, 8 kW for open-plan up to 80.
- Whole house ducted: about 1.1 kW to 1.4 kW for every 10 square metres covered, less once zoning is factored in.
- Go up a size for ceilings above 2.4 metres, no insulation or big west-facing glass. Stay at the bottom of the range for a well-insulated, shaded room.
- On the Sunshine Coast, an oversized unit is the common mistake: it short-cycles, never dries the air and leaves the room cold and clammy.
What size air con do I need? For a single room on the Sunshine Coast, roughly 2.5 kW of cooling for a bedroom up to 20 square metres, 3.5 kW for 20 to 30 square metres, 5 kW for 30 to 40, 5 kW to 6 kW for a living area of 40 to 60 square metres, and 7 kW to 8 kW for open-plan spaces beyond that. For a whole house, a ducted system (one unit in the roof feeding outlets in every room) needs about 1.1 kW to 1.4 kW for every 10 square metres it covers, before zoning. Those numbers assume a 2.4 metre ceiling, roof insulation, and windows that don’t cope with full western sun.
An online calculator will not tell you that, between Caloundra and Noosa, humidity affects your comfort as much as temperature, and a system that is too big handles humidity worse than one slightly too small. I have been sizing systems here since 2011 and I still measure every room before I put a size on a quote.
How much air con do I need per square metre?
The working rule across the trade is 110 to 140 watts of cooling per square metre of floor, which is the 1.1 kW to 1.4 kW per 10 square metres the Victorian Government publishes for ducted systems. CHOICE’s room-size table lands in the same place: 2 kW to 2.5 kW for a room up to 20 square metres, climbing to 6 kW to 9 kW past 80.
Then you adjust. A 2.7 metre ceiling holds about 12 per cent more air than a 2.4 metre one, and a 3 metre raked ceiling in a Maleny or hinterland home holds 25 per cent more, so go up a size. No ceiling insulation under a dark tin roof: up a size. A west-facing wall of glass in a Buderim living room with no eaves: up a size, sometimes two. A well-insulated bedroom with a south-facing window sits at the bottom of its range.
One warning from CHOICE that matches what I see on the coast: installer and manufacturer calculators tend to overestimate. Treat their number as a ceiling, not a target. AIRAH’s FairAir calculator is a useful free tool because it asks about insulation, glazing and climate region.

Single room split system sizes by room size
A split system is one indoor wall unit paired with one outdoor unit, the standard setup for cooling a single room.
- 2.5 kW: bedrooms, studies and nurseries up to about 20 square metres
- 3.5 kW: main bedrooms and small living rooms, 20 to 30 square metres
- 5 kW: living rooms and open kitchen-dining areas, 30 to 40 square metres
- 5 kW to 6 kW: large living areas, 40 to 60 square metres
- 8 kW: open-plan living of 60 to 80 square metres, or a smaller space with high ceilings and a lot of glass
These are the working ranges we use at Arctic, cross-checked against the CHOICE and Victorian Government tables. On a boundary, say a 21 square metre bedroom, the 2.5 kW will do it in a well-insulated brick home, and the 3.5 kW is the safer pick in a Queenslander with a tin roof and no sarking.
Above 8 kW in one room, you are usually better off with two smaller heads or a ducted zone. One big wall unit cannot push cool air to the far end of a long room, so you get a cold spot under the unit and a warm one by the dining table.
Why is an oversized air con a problem on the Sunshine Coast?
An oversized air conditioner cools the air quickly, hits the set temperature and backs off before it has run long enough to pull moisture out of the air. The room ends up cold and clammy. On the Sunshine Coast, where January humidity sits around 70 per cent in the afternoon, that is the most common complaint I hear about big systems.
Dehumidifying happens when warm, wet air passes over a cold coil and the moisture condenses and runs down the drain. A unit 50 per cent too large reaches 24 degrees in a few minutes, drops to a trickle or shuts off, and the moisture stays in the room. CHOICE lists the results as inadequate dehumidification, higher running costs and extra compressor wear. I would add mould on the louvres within two summers.
Undersized is a different kind of wrong: the unit runs flat out all afternoon and never quite gets there. On the coast that one is rare. Most of the systems I replace were too big.
The Bureau of Meteorology’s record for Sunshine Coast Airport puts the January mean maximum at 29.1 degrees with 3 pm humidity of 70 per cent. Size for that, not the 38-degree day that turns up once a summer. A correctly sized inverter (a unit whose compressor varies its speed instead of switching on and off) runs at part speed through those afternoons, and part speed is what controls humidity.
Whole house: multi-head or ducted?
A multi-head system is one outdoor unit running two to five indoor wall units, each sized as a single room split: a 2.5 kW head in each bedroom of a Mooloolaba unit, say, off one outdoor unit on the balcony. Ducted is one fan coil in the roof, outlets in every room, and zone dampers that shut off rooms you are not using.
My rule: three rooms or fewer and a tight roof space, go multi-head. The whole house, a roof cavity you can get into, and plans to stay more than five years, go ducted. Ducted is quieter inside, and with iZone zoning you can run two bedrooms at night without cooling an empty lounge.
How do you size a ducted system?
Start with 1.1 kW to 1.4 kW per 10 square metres of the area you are covering, then take off what zoning gives you. If you will never run the bedrooms and the living area flat out together, we size for the biggest combination you will actually run. A 200 square metre home on paper wants 22 kW to 28 kW. A well-zoned one often does the job on a good deal less.
Ceiling height and roof insulation matter more for ducted, because you are paying for every cubic metre across the whole house. No insulation? Spend on that first and a smaller ducted system second.

What I measure on a site visit before I put a size on the quote
- Floor area and ceiling height of each room, measured on the day, not taken from the plan
- Which way the big windows face and what shades them: eaves, trees, the neighbour’s wall
- Roof colour, and whether there is insulation in the ceiling and walls
- Who uses the room and when (a home office at 2 pm is a different load from a bedroom at 10 pm)
- Heat from inside: ovens, fridges, computers, a drinks fridge in the games room
- What the switchboard can take, and where the outdoor unit can go
- For ducted: roof space, and which rooms you will actually run together
The visit takes about half an hour, and the quote is free. I would rather spend that half hour than fit a 7 kW where a 5 kW belonged and take a call in February about the clammy air.
What does the right size air con cost?
We quote every install after a site visit, so there is no price list here. The step up from one split size to the next is usually a small part of the whole job, while a unit two sizes too big costs you in comfort and running cost every summer.
Heating and cooling account for 20 to 50 per cent of energy use in Australian homes depending on climate zone, according to energy.gov.au, and every degree you raise the cooling set point saves up to 10 per cent on cooling costs. A right-sized inverter at 24 degrees, running all afternoon steadily, is the efficient way through a Queensland summer. A 9 kW unit blasting a 30 square metre room to 20 degrees, then switching off, is not.
Not sure what size air con you need?
About the Author
Jye Storen, Owner & Director, 15+ years experience
Jye Storen founded Arctic Airconditioning & Refrigeration in 2011 and still runs it from the company’s Bells Creek workshop. He has spent more than 15 years installing, servicing and repairing cooling and refrigeration systems in homes and businesses between Caloundra and Maroochydore.